RSV-CG/CG-SD Series VAV/CAV Terminals

Overview

Rectangular VAV terminal units for standard applications regarding the supply air or extract air control in variable air volume systems

-Suitable for the control of volume flow rate, room pressure or duct pressure
-Suitable for airflow velocities up to 10 m/s

Optional equipment and accessories
-Silencer(AI) for the reduction of air-regenerated noise
-Electric heater (E) for reheating the airflow
-Hot water coil (W) for reheating the airflow


客服

Online Service

call

Enquiry

未标题-1.jpg

未标题-2.jpg

PRODUCT INFORMATION & FEACTURES
MODELCG SERIES
TYPE Single Duct Rectangular Terminal Units
NAMESquare Single Duct VAV/CAV Terminals
APPLICATIONRegulating airflow and temperature in single duct air distribution systems
APPLICATION TYPEAir handling unit to control fresh air or return air, and supply air duct to control airflow
CONTROL SYSTEMPneumatic, analog and Direct Digital Control (DDC) networked, wireless, or standalone
VOLUME SYSTEMConstant volume and variable volume systems-CAV & VAV system
APPLICATION SYSTEMCooling only/Cooling with reheat/Heating only
AIRFLOW PRESSUREPressure dependent or independent airflow control
CONTROL STAGESinclude constant volume, constant pressure and variable volume, variable pressure
CASING/HOUSINGGalvanized Steel
KEY WORDSAir handling unit, Air Valve, Air Damper, Air Regulator, VAV CAV Terminal Unit Box
OEM & ODM SERVICEACCEPTABLE, please send us your requirements


图片1.png

图片2.png

图片3.png

图片4.png

图片-5.jpg

图片-6.jpg

Square Single Duct VAV/CAV Terminals (RSV-CG)

未标题-1.jpg

Square Single Duct VAV/CAV Terminals (RSV-CG)

未标题-2.jpg

RSV-CG Series-Single Duct Rectangular Terminal Units

♦ Royal Service single duct terminals units are designed to control air flow in systems, for supply or return air for conditioned zones, spaces and occupied areas that require low or high volume. Low pressure drop characteristics enhance the applications for new or retrofit projects. Control options are pneumatic, analog and Direct Digital Control (DDC) networked, wireless, or standalone. Efficient enough for clean designs and low pressure drops

♦ Roval Service grille-type grid flow sensors assures low and high flow readings. Amplification is read by the controller's pressure sensor and flow is determined by each controller.  Multiple-port readings aluminum sensor for extended use and resistance to damage from mishandling.

♦ Damper shaft construction carbon steel and zinc plated, diameter V" (12 mm) Standard actuators attached to the shaft are easily set in place with a score shaft end for direction of open and close.

♦ External Duct work connects to the CG flange or the CG S and drive inlet and outlet.

♦ The control opposed blade damper is radius formed for a smooth flow constructed from aluminum sealed to each side for minimal air leakage. Each damper is interlocked with steel wheels to assure free movement and long operation. Between each blade air is sealed with a gasket.


This type of VAV/ CAV type at the end of simple, direct selection depending on the duct size, optional factory preset volume, optional limited to avoid on-site calibration.


CG-VAV/ CAV end install ation direction is according to the air flow direction. The primary air connection /air-supply duct-work is recommended a length that the is not less than the equivalent of three times the round duct equal of the rectangle size. Hanging the unit requires strut to hold the unit from the bottom of the unit. Install two struts and use approved hanging rod to secure the struts to the structure Level the unit and secure unit to the strut as required. The clearance for the control box recommended distance of 300mm fir installation and maintenance space (not shown) Wrap insulation can wrap the unit and as required after units are hung installed and sealed Y"Foil face wrap is one type of insulation